Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Diagnostics (Basel) ; 14(4)2024 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-38396456

RESUMO

Background: Delayed Post-Hypoxic Leukoencephalopathy (DPHL), or Grinker's myelinopathy, is a syndrome in which extensive changes are seen in the white matter of the cerebral hemispheres with MRI weeks or months after a hypoxic episode. T2-weighted spin echo (T2-wSE) and/or T2-Fluid Attenuated Inversion Recovery (T2-FLAIR) images classically show diffuse hyperintensities in white matter which are thought to be near pathognomonic of the condition. The clinical features include Parkinsonism and akinetic mutism. DPHL is generally regarded as a rare condition. Methods and Results: Two cases of DPHL imaged with MRI nine months and two years after probable hypoxic episodes are described. No abnormalities were seen on the T2-FLAIR images with MRI, but very extensive changes were seen in the white matter of the cerebral and cerebellar hemisphere on divided Subtraction Inversion Recovery (dSIR) images. dSIR sequences may produce ten times the contrast of conventional inversion recovery (IR) sequences from small changes in T1. The clinical findings in both cases were of cognitive impairment without Parkinsonism or akinetic mutism. Conclusion: The classic features of DPHL may only represent the severe end of a spectrum of diseases in white matter following global hypoxic injury to the brain. The condition may be much more common than is generally thought but may not be recognized using conventional clinical and MRI criteria for diagnosis. Reappraisal of the syndrome of DPHL to include clinically less severe cases and to encompass recent advances in MRI is advocated.

2.
Quant Imaging Med Surg ; 13(10): 7304-7337, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37869282

RESUMO

This review describes targeted magnetic resonance imaging (tMRI) of small changes in the T1 and the spatial properties of normal or near normal appearing white or gray matter in disease of the brain. It employs divided subtracted inversion recovery (dSIR) and divided reverse subtracted inversion recovery (drSIR) sequences to increase the contrast produced by small changes in T1 by up to 15 times compared to conventional T1-weighted inversion recovery (IR) sequences such as magnetization prepared-rapid acquisition gradient echo (MP-RAGE). This increase in contrast can be used to reveal disease with only small changes in T1 in normal appearing white or gray matter that is not apparent on conventional MP-RAGE, T2-weighted spin echo (T2-wSE) and/or fluid attenuated inversion recovery (T2-FLAIR) images. The small changes in T1 or T2 in disease are insufficient to produce useful contrast with conventional sequences. To produce high contrast dSIR and drSIR sequences typically need to be targeted for the nulling TI of normal white or gray matter, as well as for the sign and size of the change in T1 in these tissues in disease. The dSIR sequence also shows high signal boundaries between white and gray matter. dSIR and drSIR are essentially T1 maps. There is a nearly linear relationship between signal and T1 in the middle domain (mD) of the two sequences which includes T1s between the nulling T1s of the two acquired IR sequences. The drSIR sequence is also very sensitive to reductions in T1 produced by Gadolinium based contrast agents (GBCAs), and when used with rigid body registration to align three-dimensional (3D) isotropic pre and post GBCA images may be of considerable value in showing subtle GBCA enhancement. In serial MRI studies performed at different times, the high signal boundaries generated by dSIR and drSIR sequences can be used with rigid body registration of 3D isotropic images to demonstrate contrast arising from small changes in T1 (without or with GBCA enhancement) as well as small changes in the spatial properties of normal tissues and lesions, such as their site, shape, size and surface. Applications of the sequences in cases of multiple sclerosis (MS) and methamphetamine dependency are illustrated. Using targeted narrow mD dSIR sequences, widespread abnormalities were seen in areas of normal appearing white matter shown with conventional T2-wSE and T2-FLAIR sequences. Understanding of the features of dSIR and drSIR images is facilitated by the use of their T1-bipolar filters; to explain their targeting, signal, contrast, boundaries, T1 mapping and GBCA enhancement. Targeted MRI (tMRI) using dSIR and drSIR sequences may substantially improve clinical MRI of the brain by providing unequivocal demonstration of abnormalities that are not seen with conventional sequences.

3.
Front Physiol ; 14: 1104838, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36969588

RESUMO

Our study methodology is motivated from three disparate needs: one, imaging studies have existed in silo and study organs but not across organ systems; two, there are gaps in our understanding of paediatric structure and function; three, lack of representative data in New Zealand. Our research aims to address these issues in part, through the combination of magnetic resonance imaging, advanced image processing algorithms and computational modelling. Our study demonstrated the need to take an organ-system approach and scan multiple organs on the same child. We have pilot tested an imaging protocol to be minimally disruptive to the children and demonstrated state-of-the-art image processing and personalized computational models using the imaging data. Our imaging protocol spans brain, lungs, heart, muscle, bones, abdominal and vascular systems. Our initial set of results demonstrated child-specific measurements on one dataset. This work is novel and interesting as we have run multiple computational physiology workflows to generate personalized computational models. Our proposed work is the first step towards achieving the integration of imaging and modelling improving our understanding of the human body in paediatric health and disease.

4.
Quant Imaging Med Surg ; 12(9): 4658-4690, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36060593

RESUMO

This paper updates and extends three previous papers on tissue property filters (TP-filters), Multiplied, Added, Divided and/or Subtracted Inversion Recovery (MASTIR) pulse sequences and synergistic contrast MRI (scMRI). It does this by firstly adding the central contrast theorem (CCT) to TP-filters, secondly including division with MASTIR sequences to make them Multiplied, Added, Subtracted and/or Divided IR (MASDIR) sequences, and thirdly incorporating division into the image processing needed for scMR to increase synergistic T1 contrast. These updated concepts are then used to explain and improve contrast at tissue boundaries, as well as to develop imaging regimes to detect and monitor small changes to the brain over time and quantify T1. The CCT is in two parts: the first part states that contrast produced by each TP is the product of the change in TP multiplied by the TP sequence weighting which is the first partial derivative of the TP-filter. The second part states that the overall fractional contrast is the algebraic sum of the fractional contrasts produced by each of the TPs. Subtraction of two IR sequences alone about doubles contrast relative to a conventional single IR sequence. Division of this subtraction can amplify contrast 5-15 times compared with conventional IR sequences. Dividing sequences can be problematic in areas where the signal is zero but this is avoided by dividing the difference in signal of two magnitude reconstructed IR sequences by the sum of their signals. The basis for the production of high contrast, high spatial resolution boundaries at white-gray matter junctions, between cerebral cortex and cerebrospinal fluid (CSF) and at other sites with subtracted IR (SIR) and divided subtracted IR (dSIR) sequences is explained and examples are shown. A key concept is the tissue fraction f, which is the proportion of a tissue in a mixture of two tissues within a voxel. Contrast at boundaries is a function of the partial derivative of the TP-filter, the partial derivative of the relevant TP with respect to f, and the partial derivative of f with respect to distance, x. Location of tissue boundaries is important for segmentation and is helpful in determining if inversion times have been chosen correctly. In small change regimes, the high sensitivity to small changes in T1 provided by dSIR images, together with the high definition boundaries, afford mechanisms for detecting small changes due to contrast agents, disease, perfusion and other causes. 3D isotropic rigid body registration provides a technique for following these changes over time in serial studies. Images showing high lesion contrast, high definition tissue and fluid boundaries, and the detection of small changes are included. T1 maps can be created by linearly scaling dSIR images.

5.
J Magn Reson Imaging ; 28(1): 121-7, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18581401

RESUMO

PURPOSE: To compare two T1-weighted (T1W) fat-suppressed sequences for 3D breath-hold pre- and postcontrast fat-suppressed T1W imaging of the female pelvis at 3T. MATERIALS AND METHODS: Pelvic MRI scans of 16 female patients were retrospectively identified who were scanned with two 3D breath-hold sequences: 1) a fast spoiled gradient echo sequence with spectral inversion at lipids (SPECIAL) (called 3D FSPGR), and 2) a dual-echo two-point Dixon (DE Dixon) sequence. Contrast between soft tissue and fat, soft tissue and fluid, and fat and fluid was measured on pre- and postcontrast images. Additionally, two readers subjectively scored the images for degree and homogeneity of fat suppression plus presence and severity of artifacts. RESULTS: Contrast between muscle and myometrium to fat was improved with the Dixon technique (0.61 vs. 0.09 and 0.7 vs. 0.3, respectively, P < 0.001). Both readers agreed that fat suppression was stronger with the Dixon sequence (P < 0.001 and P = 0.06). Artifacts were equivalent (P = 0.53 and 0.65). CONCLUSION: The 3D DE Dixon sequence achieved stronger fat suppression in the female pelvis when compared to a 3D FSPGR sequence with SPECIAL.


Assuntos
Imageamento por Ressonância Magnética/métodos , Pelve/anatomia & histologia , Feminino , Humanos , Estudos Retrospectivos
6.
Magn Reson Imaging Clin N Am ; 15(3): 433-48, viii, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17893061

RESUMO

Over the past several years, evidence supporting the use of MR imaging in the evaluation of prostate cancer has grown. Almost all this work has been performed at 1.5T. The gradual introduction of 3T scanners into clinical practice provides a potential opportunity to improve the quality and usefulness of prostate imaging. Increased signal to noise allows for imaging at higher resolution, higher temporal resolution, or higher bandwidth. Although this may improve the quality of conventional T2-weighted prostate imaging, which has been the standard sequence for detecting and localizing prostate cancer for years, the real potential for improvement at 3T involves more advanced techniques, such as spectroscopy, diffusion-weighted imaging, dynamic contrast imaging, and susceptibility imaging. This review presents the current data on 3T MR imaging of the prostate as well as the authors' impressions based on their experience at Yale-New Haven Hospital.


Assuntos
Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico , Meios de Contraste , Imagem de Difusão por Ressonância Magnética/métodos , Humanos , Linfonodos/patologia , Espectroscopia de Ressonância Magnética , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...